EasyManua.ls Logo

Johnson Controls Tyco 8200-1466-01 - Installation and Enclosures; Plastic Enclosure

Johnson Controls Tyco 8200-1466-01
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Signal Power Requirements To AWG Shield Maximum Length
Power over
Ethernet (PoE)
IEEE 802.3af (PoE) and 802at
(PoE Plus), 25.5W max. LLDP
supported for PoE Plus
1
Switch Contact 24 Yes 328 ft. (100m)
Local Power
12 or 24Vdc 25.5W
max.
2
P1 18 No Maximum length depends on
application and AWG
Installation and Enclosures
The following sections describe features and installation procedures of the plastic and metal enclosures with the IP-
ACM Ethernet Door Module v2.
Plastic enclosure
Figure 2 on Page 6 and Table 5 on Page 6 describe the dimensions of the plastic enclosure. The plastic enclosure is not
acceptable for use in a plenum.
Figure 2:Plastic enclosure mounting hole dimensions
Table 5:Plastic enclosure dimensions
Plastic Enclosure Dimensions
Item Dimension
Weight 1.6lb (.72kg)
1
Compliance with IEEE 802.3 (AT or AF) specifications was not verified as part of UL294/B.
2
Maximum combined output limit for readers and locks is 17W (+/- 10%).
6

Related product manuals