JOHNSON CONTROLS
23
SECTION 2 - INSTALLATION
FORM 160.75-N1
ISSUE DATE: 04/15/2019
2
TABLE 1 - AVAILABLE COMPRESSOR/SHELL/MOTOR COMBINATIONS
YK MOD G COMBINATIONS
COMPRESSOR
CODES
EVAPORATOR
CODES
CONDENSER
CODES
MOTOR CODES
60 HZ 50 HZ
Q3 AP to AS AP to AS
CF-CT
EF-ET
5CC-5CO
5EC-5EO
Q3, Q4
CP to CS CP to CS
DP to DS DP to DS
Q4 EP to ET EP to ET
Q5
CP to CS CP to CS
CH-CT
EH-ET
5CE-5CO
5EE-5EO
DP to DS DP to DS
Q5, Q6, Q7
EP to ET EP to ET
FQ to FT FQ to FT
P7
EP to ET EP to ET
CU-CY
EU-EY
5CP-5CU
5EP-5EU
FQ to FT FQ to FT
P8 GQ to GS EV to EX
CH-CZ
EH-EZ
5CE-5CU
5EE-5EU
P8, P9
HQ to HS FV to FX
JP to JS JP to JS
LQ to LS LQ to LS
H9
KP to KS, K2 to K4 KP to KS, K2 to K4
CN-CA
EN-EA
5CK-5CW
5EK-5EW
MQ to MS, M2 to M4 MP to MS, M2 to M4
K1 KT to KX, K5 to K7 KP to KS, K2 to K4
CS-DC
ES-FC
5CN-5DC
5EN-5FB
K1, K2
MQ to MS, M2 to M4 MP to MS, M2 to M4
NQ to NS, N2 to N4 NP to NS, N2 to N4
PQ to PS, P2 to P4 PQ to PS, P2 to P4
QQ to QS, Q2 to Q4 QQ to QS, Q2 to Q4
K3
NQ to NS, N2 to N4 NP to NS, N2 to N4
DA-DJ
FA-FD
5DA-5DH
5FA-5FB
QQ to QV, Q2 to Q4 QQ to QS, Q2 to Q4
RQ, RS, RN, R3, R5, R7 RQ, RR, RS, R2, R3, R4
K4
RP, RR, RT, R2, R4, R6 RQ, RR, RS, R2, R3, R4, R5
DA-DJ
FA-FD
5DA-5DJ
5FA-5FB
SQ, SS, SV, S3, S5, S7
SQ, SR, SS, S2, S3, S4
VP, VQ, VR, VS, V2, V3, V4, V5
XQ, XR, XS, X2, X3, X4
TP, TQ, TR, TS, T2, T3, T4, T5
XQ, XR, XS, X2, X3, X4
K7
WP, WR, WT, W1, W2, W4, W6 WQ, WR, WS, W1, W2, W3, W4
DD-DL 5DD-5DL
ZQ, ZR, ZS, Z1, Z2, Z3, Z4 ZQ, ZR, ZS, Z1, Z2, Z3, Z4
INSTALLATION CHECK – REQUEST FOR
START-UP SERVICE
The services of a Johnson Controls representative will
be furnished to check the installation and supervise the
initial start-up and operation on all chillers installed
within the Continental United States.
After the unit is installed, piped and wired as described
in this Instruction, but before any attempt is made to
start the unit, the Johnson Controls District Office
should be advised so that the start-up service, included
in the contract price, can be scheduled. Use the Instal-
lation Checklist and Start-up Request (Form 160.75-
CL1).

Table of Contents

Other manuals for Johnson Controls YORK YK Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls YORK YK Series and is the answer not in the manual?

Johnson Controls YORK YK Series Specifications

General IconGeneral
BrandJohnson Controls
ModelYORK YK Series
CategoryChiller
LanguageEnglish

Related product manuals