2.9 LOUDSPEAKERS
A PA/GA system like the Compact MPA will ulize a wide variety of loudspeakers in the distribuon network. Consideraons
such as environment, topology and sound pressure requirement will determine what kind of loudspeaker type and size
should be used in the specic areas.
To comply with the environment requirement all loudspeakers used in a PA/GA system must be approved according to
relevant parts of IEC60945 or similar.
The topology and sound pressure requirement will be decisive for the number of loudspeakers in the dierent areas, the
loudspeaker type, their power rang and tapping.
See secon 5.2.3 for detailed loudspeaker selecon informaon.
3 TECHNICAL DATA
3.1 MPA 1600 OPERATION UNIT
19" 1 Unit rack mounng unit.
Operang voltage: Dual 24VDC – primary (AC through integrated Power supply module) / backup
Current drain maximum: 5A
Microphone input level: 5mV.
External PA input level: 0 dBu typical (congurable)
External entertainment input level: 0 dBu typical (congurable)
Audio outputs to ampliers: 0 dBu typical (congurable)
Size: 44 x 483 x 206 mm (HxWxD)
Weight: 3 kg
Ingress Protecon (stand-alone) (IP): 22
Compass safe distance: Ref Cabinet data
3.2 MPA 1601 PA CONTRON UNIT
Outer dimensions: 144 x 144 mm.
Operang voltage: 24VDC supplied from the MPA1600 Operaon Unit.
Current drain maximum: 300mA. (integrated in the MPA 1600)
Microphone input level: 10mV typical (dynamic mic.)
Ingress Protecon (IP): 44
Compass safe distance (standard) 80 cm
Compass safe distance (steering) 50 cm