Fault Lock Status Debug Method
a. Check gas supply system
b. Check whether combustion inlet and outlet are blocked
c. Check the flame sensor
a. Check the flame sensor lead wire
b. Check the flame sensor
Warm air outlet overheats
a. Check whether air outlet is blocked
Warm air overheats switch protection.
a. Check whether air outlet is blocked
b. Check warm air overheat switch
a. Check whether water depletion in the tank
b. Check if the sensor is in good condition
c. Check whether air outlet is blocked
Water overheat switch protection.
a. Check whether air outlet is blocked
b. Check water overheat switch
a. Check whether air outlet is blocked
b. Check water temperature sensor
c. Check warm air sensor
a. Check interconnecting cable
a. Check gas valve coil and lead wire
a. Replacement motherboard
Combustion support fan disconnection
a. Check combustion air blower
Combustion support blower boot failure
a. Check the blower motor lead wire
b. Check combustion air blower