7 Tools and Setting/Serviceman Menu
7-27
ECDIS
7.20 Radar Initial Setup
This function sets [Echo Noise Level] of [Signal Processing], [MBS Level] and [MBS Area] about the
radar.
1) Select [Menu] - [(7)Main] - [(5)Code Input] in that order.
2) The “Code Input” panel opens. After inputting [0], left-click [OK] button.
3) Select [Menu] - [(1)Serviceman menu]-[(6)Radar Initial Setup]
4) The “Radar Initial Setup” panel opens.
5) Input a value to each item or adjust that with
.
• Signal Processing: Setting the echo noise level of Signal Processing.
• MBS: Setting the level and area of Main Bang Suppression.
6) Left-click the [OK] on the panel to close the panel.
It closes a panel without changing contents when clicking the [Cancel] button.
It saves contents without closing a panel when clicking [Apply] button.
MBS Area:
MBS area can be set between from 0 to
255.
MBS Level:
MBS Level can be set between from 0 to
255.
Setting Mode:
On/Off of Setting Mode can be changed.
Echo Noise Level:
Echo Noise Level can be set between
from 0 to 255.