Table 7-1: ERROR code table of the Operation Panel Unit (3/3)
ALARM DETAIL
SYSYTEM CODE
CATEGORY
CONTENTS
7 0
FGB CH1 Radar image data error
The FGB does not receive RGB signals from Radar connected to CH1.
7 1
CH2 Radar image data error
The FGB does not receive RGB signals from Radar connected to CH2.
7 2
FGB Communication error
The MCB does not communicate with the FGB normally via LAN.
7 3
FGB Setup data reception error
The MCB does not receive the setup data of FGB successfully.
7 4
FGB Control error
The MCB did not communicate with FGB successfully.
7 5
FAN alarm of NWP-46
FAN built in NWP-46 (Radar Interface Unit) is out of order.
7 6
FGB Real time monitor data transmission error
The IP address for transmitting image data is not registered in the FGB yet.
8 0
RMB communication error
The MCB do not communicate to the RMB normally via LAN.
RMB
RMB Control error
The MCB is unsuccessful in control of the RMB.