14. Maintenance Check List
JCY-1800/1850 VDR/S-VDR Installation Guide
173
DOC No. 7ZPJD0387C
3. The total check after power on
No. Check items Check Name of check person Modification operations Remark
3.1 Checking record data of CF CARD
Data of recording to CF CARD are checked in the following procedure.
1) Press the CARD Stop switch on the internal operation panel of RCU.
2) After CARD lamp is off. Eject CF CARD and press the CARD Eject
button.
3) Set the CF card to adaptor appended to the RCU.
4) Insert CF card into the PCMCIA slot of maintenance PC.
Start up the Playback software in Maintenance software.
Copy to HDD from CF CARD by the Playback software.
5) Eject CF CARD after it is enable to eject from PCMCIA slot of
maintenance PC. Insert the CF card without adaptor to CARD slot of
RCU.
6) Check the CARD lamp on the internal operation panel of RCU light up.
7) Check that record data is recorded normally by the Playback software.
3.2 Checking record data of PCU
Data of recording to PCU are checked in the following procedure.
1) Click the REC stop button on the internal operation panel of RCU.
2) Check that the RECORD LED puts out the light.
3) Download a record data from the Capsule by the Playback software in
Maintenance software. Set the backup data size as 5%.
4) Check that record data is recorded normally.
3.3 Checking Blackout detection
Blackout detection function is checked in the following procedure.
1) Push the Blackout Test switch on the Power Supply Unit of RCU for 3
seconds.
2) Confirm that BATTERY OP. LED on the Power Supply Unit of RCU
lights up.
3) Confirm that Power LED is blinking and blackout alarm (error code:
10__) is indicated on the OPU.