Data items
Date and time of
confirmation
Alarm on the
bridge
Recorded alarm
data
Judgment Notes
16 Fire detection in automated or remotely
controlled machinery space
Audible
+Visual
Audible
+Visual
G. / N . G.
Activation of detection system
17 Fire detection or automatic
sprinkler operation
Audible
+Visual
Audible
+Visual
G. / N . G.
Activation of sprinkler or fire detection system. Also additional alarm
to show fault or loss of power to either system
18 Smoke detection system power loss *
b
Audible
+Visual
Audible
+Visual
G. / N . G.
Sample extraction smoke-detection systems. Failure of power to the
system
19 Smoke detection *
b
*
c
Audible
+Visual
Audible
+Visual
G. / N . G.
Equipment item 18. Activation of system
20 Halon system loss of container *c
Audible
+Visual
Audible
+Visual
G. / N . G.
Decrease in pressure of gas in containers
21 Halon system electric circuit fault
of power loss *c
Audible
+Visual
Audible
+Visual
G. / N . G.
Failure of electric power to circuits connecting containers for gas
release
22 Halon system –hydraulic or pneumatic
pressure loss
*c
G. / N . G.
Loss of pressure to pneumatic or hydraulic circuit for gas release
23 Personnel alarm
Audible
+Visual
Audible
+Visual
G. / N . G.
Safety. Personnel on watch alone in an engine room or entering
machinery space alone
*
a
These tables do not include the alarms separately identified for specialist vessels such as gas carriers, fishing vessels, nuclear ships, high-speed craft or mobile offshore drilling
units.
*
b
Applicable to vessels constructed on or after February 1992.
*
c
These alarms may be omitted if they are provided at the central fire control station.