1. Specifications
JCY-1800/1850 VDR/S-VDR Installation Guide
23
DOC No. 7ZPJD0387C
2) Current: +/-20mA
c) Communication port Same port as dry contact signals
d) Data output interface Data type: IEC61162-1
Analog Sentence formatter: XDR
(4) Environmental condition:
a) Operating temperature: -15°C to +55°C (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(5) General specification
a) Power voltage: 100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 25VA
c) Size: 300(w) x 130(d) x 230(h) mm
d) Mass: 2.9kg
e) Color: N7 semi-gloss
1.10.9. Radar Interface Unit (NWP-46) -Option-
(1) Function:
The NWP-46 is required when a high resolution (UXGA) radar display is
connected to the VDR/S-VDR.
The NWP-46 is an option unit in order to install a FGB near the radar, because
high resolution RGB signals can not be extended to the VDR/S-VDR,
The Frame Grabber Board (FGB) in the NWP-46 is moved from the Recording
Control Unit.
(2) Performance:
a) Basic performance: It is the same as the Radar image input specification of the Recording Control
Unit.
b) Communication port To the NDV-1800/1850 RCU via Ethernet
(3) Environmental condition:
a) Operating temperature: -15°C to +55°C (IEC 60945 protected type)
b) Temperature and humidity: +40°C, 93%
c) Vibration: 2Hz to 13.2Hz ±1.0mm
13.2Hz to 100Hz 0.7G
(4) General specification
a) Power voltage: 100 - 120VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
200 - 240VAC +/- 10% 1-phase 50/60Hz (IEC 60945)
b) Power consumption: 10VA
c) Size: 255(w) x 160(d) x 72(h) mm
d) Mass: 1.5kg
e) Color: N4 semi-gloss