4. Cabling
JCY-1800/1850 VDR/S-VDR Installation Guide
69
DOC No. 7ZPJD0387C
5) JMA-9000 / 7000 series
Resolution 1312 x 928 pixel
Scan Non-interlaced
Color Monochrome
Output Signal VD / Vs / Hs
Connector BNC
Vertical Refresh rate 45.5 Hz
Sync Impedance 75 ohms
Signal level +5.0 - 0V at 2.2k ohms termination
+2.5 - 0V at 75 ohms termination
Polarity Negative
Horizontal Frequency 43.88 kHz
sync Impedance 75 ohms
Signal level +5.0 - 0V at 2.2k ohms termination
+2.5 - 0V at 75 ohms termination
Polarity Negative
Video Pixel frequency 67.4043 MHz
signal Impedance 75 ohms
Signal level +0.7 - 0V
Polarity Positive
*To make the output to the VDR viable, please incorporate an amplifier (NAD-30)
and VDR connection kit (MPBC35722) into the RADAR equipment, using a kit
provided by JRC.
* JMA-9000/7000 series Radar could be connected to the S-VDR
6) JMA-7700 series
Resolution 1024 x 768 pixel
Scan Non-interlaced
Color Color
Output Signal R / G / B / Vs / Hs
Connector BNC
Vertical Refresh rate 68.6 Hz
sync Impedance 75 ohms
Signal level +5.0 - 0V at 2.2k ohms termination
+2.5 - 0V at 75 ohms termination
Polarity Negative
Horizontal Frequency 54.44 kHz
sync Impedance 75 ohms
Signal level +5.0 - 0V at 2.2k ohms termination
+2.5 - 0V at 75 ohms termination
Polarity Negative
Video Pixel frequency 71.4286 MHz
signal Impedance 75 ohms
Signal level +0.7 - 0V
Polarity Positive
*To make the output to the VDR viable, please incorporate a VDR connection kit
(CFQ-8914, CQD-1891) into the RADAR equipment, using a kit provided by JRC.