4. Cabling
JCY-1800/1850 VDR/S-VDR Installation Guide
74
DOC No. 7ZPJD0387C
4.2.12. Recording Control Unit NDV-1800/1850 – External Alarm Lamp
Connect the RCU to the External Alarm Lamp, which is incorporated into the External Alarm Console.
- Connecting the two lines [A]-[C]: Normal open contact
- Connecting the two lines [B]-[C]: Normal close contact
Once an alarm is detected in the VDR, the alarm status is displayed. When everything has been restored,
the normal status is displayed.
Connection table for External Alarm Lamp:
RCU
Term #
External Alarm Console
Remarks
CQD-2040
TB406
ERROR
3 [A] Normal Open Contact
4 [C] Common
5 [B] Normal close Contact
Cable Specification 2 (wires) x 0.75 mm
2
4.2.13. Recording Control Unit NDV-1800/1850 – External Alarm Buzzer
Connect the RCU to the External Alarm Buzzer, which is incorporated into the External Alarm
Console.
- Connecting the two lines [A]-[C]: Normal open contact
- Connecting the two lines [B]-[C]: Normal close contact
Once an alarm is detected in the VDR, the alarm status is displayed. Press the [ACK] switch, and the
normal status is displayed.
Connection table for External Alarm Buzzer:
RCU
Term #
External Alarm Console
Remarks
CQD-2040
TB406
ALARM
6 [A] Normal Open Contact
7 [C] Common
8 [B] Normal close Contact
Cable Specification 2 (wires) x 0.75 mm
2