Chapter9 Appendix
VDR/S-VDR Real Time Monitor / Installation Manual
78
9.2.3 Example3
In case of connecting with Client PC and Radar IF
IP address assignment of Server and Client PC is default, and explains how to set when Server
PC is connected to Client 1, Client 2, Client3 PC and Radar IF.
VDR/S-VDR Real Time Monitor & Onboard LAN (Example) INTERCONNECTION DIAGRAM
VDR IF(Router)
VDR/S-VDR
Real Time Monitor
Server PC (*2)
VDR/S-VDR
Real Time Monitor
Client PC1 (*2)
VDR/S-VDR
Real Time Monitor
Client PC2 (*2)
VDR/S-VDR
Real Time Monitor
Client PC3 (*2)
On Board LAN System (Example)
AC
LAN
LAN
LAN
JCY-1800/1850
VDR/S-VDR
EXT-LAN *3
*1 Ethernet cable
(Shield Twist-Pair cable)
Max. 30m
NOTE
1. *1 Shielded LAN Cable(Cat5) : Dock Yard supply
2. *2 PC : Owner supply
3. *3 JCY-1800 : EXT-LAN
JCY-1850 : JRC-LAN
LAN
RJ-45
NWP-46
Radar IF
LAN
HUB
WAN
LAN
192.168.0.254
192.168.0.251
192.168.0.250
192.168.0.249
192.168.0.248
192.168.111.100
192.168.0.100
192.168.111.152
Note
Radar IF (NWP-46)
In the VDR/S-VDR equipment main Radar image is captured
and recorded, and it is possible to capture or record images of
sub Radar and ECDIS by the Radar IF in the VDR/S-VDR Real
Time Monitor.