5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
83
DOC No. 7ZPNA4014
6) [Alarm Mute] button
The [Alarm Mute] button is used to prohibit the ALARM BUZZER of OPU.
Click the [Alarm Mute] button. Even if an error occurs during a maintenance communication link, an ALARAM
BUZZER does not sound.
The color of [Alarm Mute] button becomes green while mute function is effective.
Click the green [Alarm Mute] button. Mute function is stopped.
Stop the mute function before exiting the Maintenance software.
7) [ACK] button ボタン
A function of [ACK] button on this screen and the function of [ACK] button on the OPU is a same.
The [ACK] button is used to stop the ALARM BUZZER.
When more than one error is detected, it should be pressed as many times as the number of the errors.
5.2. Sensor section
The equipment information and recording data registered by detailed setup of sensor is displayed.
Click the [Unit ID / Record item]/ [Manufacturer / Model] button.
Displayed information and displayed button name is changed.
* ID number is a error code which is displayed on the OPU.
Change of display