6-11
Connection to gyro (if docking-log option is used)
Term# Function Note
3A NMEA in 3 Connect to NMEA "A" output terminal from
ro
3B NMEA in 3 Connect to NMEA "B" output terminal from
ro
Instead of a serial NMEA interface an analogue signal can be used to obtain rate of turn
information from the gyro.
Term# Function Note
17 Si
n. Analo
ue in Connect to analo
ue output si
nal from
ro
17 0VDC Analo
ue in Connect to si
nal
round from
ro
Note! The gyro output impedance may not exceed 150: when using the analogue input.
NWW-82 Speed Log Master Display and redundancy displays
Term# Function Note
37A NMEA out 2 Connect to NWW-82 NMEA "A" input
37B NMEA out 2 Connect to NWW-82 NMEA "B" input
6A NMEA in 6 Connect to NWW-82 NMEA "A" output
6B NMEA in 6 Connect to NWW-82 NMEA "B" output
50+ +12 to 28 VDC Connect to DC power input of displa
. Fuse F301
50- 0 VDC Connect to DC power input of displa
The speed logs and the Sig. Distributor menu system can be remotely accessed for calibration
and setup of parameters from an NWW-82 Main Display(Master Display).
The NMEA out 2 and NMEA in 6 shall be connected to the NMEA in and out connections of
the SD4 via a twisted pair cable. It is recommended to use a shielded cable with four twisted
pairs to connect the SD4 to the Sig. Distributor, two pairs for NMEA, one pair for power and
one pair as spare. NMEA out 2 will be directly connected, via redundancy relays, to NMEA in
5 (the redundancy output of speed log1) in case of loss of power or a failure in the Sig.
Distributor.
2
nd
Display Log remote control
Term# Function Note
44A NMEA out 9 Connect to NWW-82 NMEA "A" input
44B NMEA out 9 Connect to NWW-82 NMEA "B" input
7A NMEA in 7 Connect to NWW-82 NMEA "A" output
7B NMEA in 7 Connect to NWW-82 NMEA "B" output
51+ +12 to 28 VDC Connect to DC power input of displa
. Fuse F301
51 0 VDC Connect to DC power input of displa
A 2
nd
Display remote control can be connected to the system. It will have the same remote
control functionality as the Speed log master display.