9-8
4.2.6 Menu A0 Internal diagnostics
The internal diagnostic code list is intended for service use to inspect
internal status. Menu A0 displays number of active and acknowledged
codes.
A0 DIAGNOSTICS
0 ACTIVE 0 ACKN
Press ENTER to go into signal list sub menus. The status in the sub
menus can be:
NORMAL: Normal condition (nothing to report).
ACTIVE: Active diagnostic condition (not acknowledged).
ACTIVE ACKN: Active diagnostic condition (acknowledged).
NOTE: Active diagnostic conditions may be transmitted on the main
serial output as $PSALW sentences if enabled in menu S3.
4.2.6.1 Menu A101 ES Simulation
This menu shows status of the echo sounder (ES) simulation (active when
menus T1–T4 for ES simulation is enabled). If the code is active it can be
acknowledged by pressing ENTER.
A101 NORMAL
ES SIMULATION
4.2.6.2 Menu A110 ES Alarm test
This menu shows status of the echo sounder (ES) test alarm (active when
Menu F1 is enabled). If the code is active it can be acknowledged by
pressing ENTER.