9-10
4.2.6.9 Menu A240 SOG / ES TX Mute
This menu shows status of the SOG / ES TX Mute signal (active when
SOG / ES TX Mute is enabled). If the code is active it can be
acknowledged by pressing ENTER.
A240 NORMAL
SOG/ES TX MUTE
4.2.7 Menu C0 Calibration
The calibration menus are used to change calibration parameters for SAL
T-series log. Ordinary users may use all menus. Press "+" or "-" to select
write access on or off, ENTER to go into calibration sub menus.
C0 CALIBRATION
WRITE ACCESS OFF
4.2.7.1 Menu C1 BT speed calibration
The bottomtrack transducer speed (magnitude) calibration factor in
percent is set with this menu. Press "+" or "-" to change the calibration
value to correspond to the result of the mile run. Save value by pressing
ENTER.
C1 BT Speed
Calibrat:rRR.RR%
4.2.7.2 Menu C2 BT angular calibration
The bottomtrack transducer angular calibration in degrees is set with this
menu. Press "+" or "-" to change the calibration value to correspond to
the result of the mile run. Save value by pressing ENTER.
C2 BT Angular
Calibrat:rRRR.R°