10-14
01D:23H:45M 354
STW SIG. BALANCE
When entering menu A2.1 the first entrance in the list is
shown. This example code 354 occurred 01 days, 23 hours
and 45 minutes after system start (viewable in menu A1)
and indicates a problem with the signal balance. Use – or +
keys to scroll the list.
A2.1 DIAG 2/10
As soon as + (or –) is pressed the next (or previous) list
position is shown for one second.
01D:23H:45M 354
STW SIG. BALANCE
The corresponding entrance in the list is then automatically
shown.
A3 ERASE HISTORY
DISABLED
Menu A3 erases the history. Use + to enable the menu and then Enter to
erase history.
4.4.4 Menu C, Calibration
The calibration menus are used to change calibration parameters for WATER TRACK U. To
be able to make changes to sub-menus write access must be activated (changed to ON) before
menu is entered.
C0 CALIBRATION
WRITE ACCESS OFF
C1 DRAUGHT COND.
FULL LOAD 0.00%
Three draught conditions are predefined: FULL LOAD, BALLAST1 and
BALLAST2. Menu C1 selects which one of the draught conditions to use.
The draught condition adjusts the output speed with the given calibration
factor. Scroll between load conditions with – or + keys. Select a condition
with Enter which will bring you to the next sub menu level.