Dimensions
LPU2 ELC: 500 x 500 x 212mm (H x W x D) + 60 mm under the LPU2 for cable gland.
NOTE: When mounting, reserve a space of at least 150 mm under the cabinet for cable routing.
Cabinet location
x The LPU2 cabinet shall be vertically mounted in a location where necessary cabling
from bridge equipment can be brought to the unit, preferably on the bridge or a space
close to the bridge.
x The location must have space enough to give sufficient space and accessibility for
service of the unit.
x The location shall be protected from weather and shall offer a stable temperature.
x The location shall not expose the unit to excessive vibration levels.
x The location shall be far from electrical installations giving excessive electric and/or
magnetic fields.
x The cabinet bottom shall be placed approximately 1.2 m from the floor where practical.
x Compass safe distance 2 meters.