JMA-9172-SA Instruction Manual > 7.SETTINGS FOR SYSTEM OPERATION > 7.3 ADJUSTMENT
[ii] Receiver Monitor Adjustment (Rx MON Adjustment)
Attension
Do not change the parameters of 6. Monitor Range and 7.Rx MON Gain.
Procedures
1) Open the Serviceman Menu.
2) Perform the following menu open procedure to open the Tx
Monitor Adjustment menu.
1.Adjust Menu
4.TXRX Adjustment
7.SSR MON Setting
5. Monitor Sector
3) The +/- button is operated so that "Rx ATT Value" may become
the maximum.
*The PM Rx area(22.5
°
) displayed on the PPI screen moves to
operate "+/-" button.
4) Perform the following menu open procedure to open the Rx
MON Adjustment menu.
5) Adjust the Rx MON Adjustment value to 0.0 ± 1.0dB by
operating the + / - button.
6) Left-click the ENT button.
The radar system is equipped with an interswitch.
For adjusting the performance unit, set the interswitch connection to
straight, i.e. No.1 scanner is connected to No.1 display unit as the Master.