EasyManua.ls Logo

JRC JMR-5410-6X - New Target Alarm Generation Conditions; Disabling AZ1 or AZ2

JRC JMR-5410-6X
640 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-3 Section 12 Setting up Alerts
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
APP A
APP B
12.3 New Target Alarm Generation
Conditions
[Operation procedure]
Open the [New Target Alarm] dialogue by performing the following menu operations.
[Menu] button Alert New Target Alarm
In this dialogue, it is possible to set the AZ (automatic acquisition/activation zone) and switch the AZ to
enable/disable.
For the details of the setting of the AZ, refer to "6.5.1.1 Automatic acquisition (automatic acquisition)
mode".
12.3.1 Switching AZ1/AZ2 to enable/disable
12.3.1.1 Enabling AZ1 or AZ2
Select the [Use AZ1] or [Use AZ2] check box.
A TT target / AIS target in the applicable AZ is automatically acquired / activated and it becomes a
target of collision detection.
A " " mark and identification number are assigned to the acquired TT target on the radar screen,
which are moved together with the TT target, and then a vector is displayed within 1 min.
12.3.1.2 Disabling AZ1 or AZ2
Clear the [Use AZ1] or [Use AZ2] check box.
Acquired and activated zones disappear from the RADAR screen. However, already acquired TT
targets are continuously tracked. Moreover, activated AIS targets remain activated.
Start angle
AZ1
AZ2
End angle
End distance
Start distance

Table of Contents