3.1.1 Power ON
Before turning on all power switches of JUE-87, confirm that all the signal cables and power cables
are connected correctly.
Step Operation/Response (Example) Screen (Example)
1 Turn on the DC switch and AC switch on the
EXT PSU.
Turn on the IME and the POWER LED of
the IME is illuminated.
The software version is displayed and
operation check.
2 The IME system software starts up in about
30 seconds,
then Main menu screen is displayed.
NOW LOADING・・・
SELF DIAGNOSING・・・
Software version :1.00
ROM
check :OK
RAM check :OK
Keyboard check :OK
3 Turn on the printer.
The status is changed “Log-out” or
“Egc-only” to “Tune” in the first line on the
main menu, then JUE-87 is started selecting
NCS common channel.
See “Fig. 3.4”
4 After few minutes, the status is changed Tune
to “Comm (TX)” or “Egc-only” in the first
line on the main menu.
After few minutes, READY LED on the IME
is lit.
The status is changed “Comm (TX)” to
“READY” in the first line on the main menu.
5 Set up each parameter following “3.5 Initial
setting”.
3.1.2 Power OFF
Turn OFF the power switch of JUE-87 with below outlined procedure.
Step Operation/Response (Example) Remarks
1 Turn off the IME.
(Press the POWER button until
POWER LED starts blink.)
Press “Power” on front of IME for 2
seconds at least.
2 The status is changed “READY” to “Comm (TX)”
in the first line on the main menu to initiate the
Log-out.
After few minutes,
POWER LED on the IME is
light OFF.
When “Log-out”, “Egc-only” or “Tune” is
displayed in the first line on the main menu, power
supply of IME is turned off automatically.
When you turned off the external
power switch, IME is turned off
without Log-out. Switch off after
check whether it has Log-out.
3 Turn off the printer.
Turn off the DC switch and AC switch on the
EXT PSU.
Switch off the external power source
from DC switch to AC switch.
If you made reverse this turn, the
power failure detection circuit works
after turn off the AC switch, and the
battery is drained until turn off the
DC switch.