4-6 Countermeasure
If the equipment does not operate normally even following procedure is performed, consult JRC
service agent. Take care not to touch any parts on PC board.
Abnormal operation of IME
In case of the heavy fluctuation of the voltage or frequency of the power source, or thunderbolt
and etc., IME may not operate normally. In this case, try following procedure (a). And try
procedure (b) when procedure (a) did not work.
(a) Set
POWER switch to OFF, and confirm all of the LED lamps are lights out (it will takes
approximately 3 minutes) and set to ON again.
(b) Press
RESET button in the IME panel by the tip of narrow object (like extended clip,φ0.5mm).
Push until you feel the object clicks. (refer fig. 4-6)
Five lamps (
POWER lamp to RECEIVE lamp) lights in order, and starts blinking (it will takes
approximately 10 seconds). Turn on POWER switch with confirming these lamps are blinking.
JUE-95LT may not reboot due to short-circuit of RESET button, if this button is pressed so strongly.
The data, which are received message, call logging history and alarm history, memorized in IME
are cleared when RESET button is pushed. Saving important data to Floppy-Disk or USB Flash
Memory is highly recommended (Prepare optional DTE, Floppy-Disk Drive (for DTE
(NDZ-127C1)), and JUE-85 instruction manual).
Fig. 4-6 IME resetting
Procedure (b)
Push the RESET Button with a stick of
wire like extended clip.
The depth of the hole is approximately
1cm. So, use the wire 2cm or more.
Procedure (a)
Set
POWER switch to OFF and set to
ON again.