4-31
4.8.8. Setting the air temperature alarm
An alarm occurs when the air temperature exceeds the set value.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Press the
key to select “ALARM” and “AIR TEMP” in order.
3. Press the
key to select “OVER,” “UNDER,” “IN RANGE,” or “OUT RANGE.”
4. Press the
key to select “OVER,” “UNDER,” “MAXIMUM,” or “MINIMUM.”
5. Press the
key to enter the air temperature, and press the key.
6. Refer to “4.8.11 Setting a buzzer sound and screen back light” to set the alarm sound and screen
brightness.
4.8.9. Setting the atmosphere alarm
An alarm occurs when the atmosphere exceeds the set value.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Press the
key to select “ALARM” and “PRESSURE” in order.
3. Press the
key to select “OVER,” “UNDER,” “IN RANGE,” or “OUT RANGE.”
4. Press the
key to select “OVER,” “UNDER,” “MAXIMUM,” or “MINIMUM.”
5. Press the
key to enter the atmosphere, and press the key.
6. Refer to “4.8.11 Setting a buzzer sound and screen back light” to set the alarm sound and screen
brightness.
4.8.10. Setting the humidity alarm
An alarm occurs when the humidity exceeds the set value.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Press the
key to select “ALARM” and “HUMIDITY” in order.
3. Press the
key to select “OVER,” “UNDER,” “N RANGE,” or “OUT RANGE.”
4. Press the
key to select “OVER,” “UNDER,” “MAXIMUM,” or “MINIMUM.”
5. Press the
key to enter the humidity, and press the key.
6. Refer to “4.8.11 Setting a buzzer sound and screen back light” to set the alarm sound and screen
brightness.