4-47
4.9.14. Demonstration
Through a demonstration, display and external output are enabled in the same way as the actual
equipment operation.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Select “DEMO MODE” and “DEMO TYPE” in this order by using
.
3. Select a DEMO condition and press .
4. Select "DEMO MODE" and "START" by using .
4.9.15. Outputting setting value
Setting value can be output to an external unit.
Data is output from a data IN/OUT1 port.
If data IN/OUT1 is set to reception, the port must be set to transmission.
Connect PC to a serial port before output operation.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Set DATA IN/OUT to “SEND” by referencing “4.9.5 Setting a serial port”.
3. Select “INTERFACE” and “DIAGNOSIS” in this order by using
.
4. When
is pressed at “CONFIG OUTPUT”, data is output to an external unit.
4.9.16. Setting the current to be displayed
You can set the layer and data No. to be displayed.
The layer that can be displayed is up to three layers from the top.
Normally, set “LAYER” for use.
Procedure
1. Refer to “4.9.1 Changing to a maintenance mode” to display the maintenance menu.
2. Press the
key to select “CURRENT.”
3. Press the
key to select “LAYER,” and press the key.
4. Press the
key to select “DATA No.,” and press the key.
During execution of demonstration, [S] is displayed in blinking mode at the bottom of the screen.
To end demonstration, set “DEMO MODE” to “END” or turn off the power.
Su