4-74
4.11 Alarm Settings
9 types of alarms can be configured. The can be individually turned off or on, and the alarm
sounds can be set individually.
The following alarms can be configured.
(1) SYSTEM: An alarm sounds when positioning is stopped. This cannot be set to Off.
(2) ARRIVAL/ANCHOR: An alarm sounds when own ship reaches or leaves the arrival
circle.
Alarms cannot be set for both arrival and departure.
(3) XTD/BOUNDARY: An alarm sounds when own ship leaves or enters the route.
Alarms cannot be set for both leaving and entering.
(4) DGPS: An alarm sounds when switching from GPS positioning to DGPS positioning, or
from DGPS positioning to GPS positioning.
(5) HDOP: An alarm sounds when the GPS positioning HDOP value exceeds the set value.
(6) TEMP: An alarm sounds when the water temperature matches the set parameters.
(7) DPTH: An alarm sounds when the water depth matches the set parameters.
(8) TRIP: An alarm sounds when the trip exceeds the set value.
(9) SPEED: An alarm sounds when the speed matches the set parameters.
Externally connected equipment is needed for water temperature or depth alarms to function.
When an alarm occurs, the alarm will sound, and a blinking icon will be displayed on the status
bar.
The alarm sound can be pressed by
, but the icon will continue appearing until the alarm
has been resolved.
If you do not want an alarm to sound, set it to "OFF".
4.11.1 Setting Alarms
Please refer to "4.20 Equipment Configuration" and switch the unit to equipment configuration
mode.
1. Press
, and then to display the alarm screen.
2. Select the alarm you wish to set.
♪: Alarm sound set
Procedure