ā 44 ā
(18) Adjustment of air nozzle (air blow)
1. Adjustment of air nozzle (air blow)
The standard poition of the nozzle
is such that it is in parallel to the throat plate . Standard forward and
backward positioning is that there is no contact when the presser
israised.
Height of the nozzle is about 23mm from the throat plate in parallel state.
23mm
Rught and left directions
Longitudinal directions
Standard Adjustment