15. ADJUSTING THE NEEDLE STOP POSITION
WARNING :
1. Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
2. Do not perform switch operations other than those described in the following explanations.
3. Be sure to re-turn the power switch ON after one second or more has passed. If the power is turned
ON immediately after turning it OFF, the sewing machine may not work normally. In this case, turn ON
the power again.
(1) Stop position after thread trimming
1) The standard needle stop position is obtained
by aligning marker dot
A
on the pulley cover
with white marker dot
B
on the handwheel
* For the details, refer to the Instruction Manual
for the control box together
.
1) T
urn OFF the power to the machine.
2) Turn the power ON while pushing the switch
5
on the operation panel.
3) The screen display
E
indicates the setting No.
96 and
F
indicates the number of revolution.
(When the screen display is not changed, oper-
ate again steps 1) and 2).
4) Update the setting No. by switch
1
or switch
2
.
Setting No. 121 : Needle UP
stop position
Setting No. 122 : Needle DOWN stop position
5) Specify the setting contents
F
within the range of -15 to 15 with switch
3
or switch
4
.
(Standard is "0".
The numeric of set value indicates the approximate rotating angle. (When the numeric
is set to the "+" direction, the needle UP stop position is lowered. (Direction
C
)
When the numeric is set to "–" direction, the needle UP stop position is raised. (Direction
D
)
6) After completion of the setting, press switch
1
or switch
2
to determine the updated value. (When turn-
ing OFF the power to the machine before performing this work, the contents are not updated.)
7) After completion of the operation, turn OFF the power to the machine. The normal operation can be per-
formed by turning ON the power to the machine again.
B
A
3
2
1
C
D
E
F
5
4
(2) Adjusting procedure of the needle up/down stop position
* When the panel other than CP-18 is used, refer to the explanation of each panel.
– 13 –