Error
code
Description of error Cause Item to be checked
E903 85-V power supply
fault
In the case the 85-V voltage is not
properly output.
Check whether the motor is faulty
Check the F2 fuse.
E904 24-V power supply
fault
In the case the 24-V voltage is not
properly output.
E910 The presser motor
origin retrieval error
In the case the presser motor has failed
to return to its origin.
Check whether the presser setting is
correct (memory switch No. 23).
Check whether the presser motor
origin has been correctly adjusted.
E912 Main shaft motor
speed detection
error
In the case the main shaft motor runs
at a speed that exceeds the assumed
speed.
Check whether connection encoder
wire of the main shaft motor is
correct.
Check whether connection of the
main shaft motor wire is correct.
E915 Failure of
communication with
operation panel
In the case the operation panel
connector is not inserted properly.
Check whether CN38 of the CTL PCB
or CN200 of the panel is connected
properly or whether the cable has
broken.
E922 Main shaft control
failure
In the case the main shaft fails to
operate as assumed.
E924 Motor driver fault In the case the motor driver has broken.
E946 Machine-head
EEPROM write error
In the case data cannot be written on
the machine-head EEPROM.
Check whether the machine-head
INT PCB is connected properly.
E955 Electric current
sensor error
The electric current of the main shaft
motor exceeds the assumed value.
Check whether connection of the
main-shaft motor wire for power is
correct.
E961 Pitch motor deviation
error
In the case the pitch motor fails to
operate because of an excessive load.
Check whether the pitch motor runs
smoothly.
E962 Presser motor
deviation error
In the case the presser fails to operate
because of an excessive load.
Check whether the presser motor
runs smoothly.
E971 Feed horizontal
motor IPM over-
current protection
Pitch motor maloperation.
E972 Feed horizontal
motor overload
In the case the pitch motor is applied
with an excessive load.
Check whether the pitch motor runs
smoothly.
E973 Feed vertical motor
IPM over-current
protection
Feed driving motor maloperation.
E974 Feed vertical motor
overload
In the case the feed driving motor is
applied with an excessive load.
Check whether the feed driving motor
runs smoothly.
E975 Presser motor
IPM over-current
protection
Presser motor maloperation.
E976 Presser horizontal
motor overload
In the case the presser motor is applied
with an excessive load.
Check whether the presser motor
runs smoothly.
E985 Return-to-origin
error of pitch motor
or feed driving motor
In the case the pitch motor has failed to
return to its origin.
In the case the feed driving motor has
failed to return to its origin.
Check whether the origin of the pitch
motor has been adjusted properly.
Check whether the origin of the feed
driving motor has been adjusted
properly.
– 54 –