- 40 -
No. Description of error detected Cause of occurrence expected Items to be checked
E303 Semicircular plate sensor
error
Semicircular plate sensor signal cannot be
detected.
Check whether the machine head
corresponds with the machine type setting.
Check whether the motor encoder connector
is disconnected.
E730 Encoder failure When the motor signal is not properly
inputted.
Check the motor signal connector (CN39) for
loose connection and disconnection.
Check whether the motor signal cord has
broken since the cord is caught in the
machine head.
Check whether the inserting direction of the
motor encoder connector is wrong.
E731 Motor hole sensor failure
E733 Inverse rotation of motor This error occurs when the motor is running
at 500 sti/min or more in the opposite
direction of that of rotation indication during
motor is running.
Connection of the encoder of main shaft
motor is wrong.
Connection for the electric power of main
shaft motor is wrong.
E808 Solenoid short circuit Solenoid power does not become normal
voltage.
Check whether the machine head cord is
caught in the pulley cover or the like.
E809 Holding motion failure Solenoid is not changed over to holding
motion.
Check whether the solenoid is abnormally
heated. (CTL circuit board asm. Circuit is
broken.
E810 Solenoid current abnormality Solenoid rare short-circuit. Solenoid resistance
E811 Abnormal voltage When voltage higher than guaranteed one is
inputted.
200V has been inputted to SC-920 of 100V
specications.
JUS : 220V is applied to 120V box.
CE : 400V is applied to 230V box.
Check whether the applied power voltage is
higher than the rated voltage + (plus) 10% or
more.
Check whether 100V/200V changeover
connector is improperly set.
In the aforementioned cases, POWER p.c.b
is broken.
When voltage lower than guaranteed one is
inputted.
100V has been inputted to SC-920 of 200V
specications.
JUS : 120V is applied to 220V box
Inner circuit is broken by the applied
overvoltage
Check whether the voltage is lower than the
rated voltage - (minus) 10% or less.
Check whether 100V/200V changeover
connector is improperly set.
Check whether fuse or regenerative
resistance is broken.
E906 Operation panel transmission
failure
Disconnection of operation panel cord
Operation panel has broken.
Check the operation panel connector
(CN34, CN35) for loose connection and
disconnection.
Check whether the operation panel cord
has broken since the cord is caught in the
machine head.
E924 Motor driver failure Motor driver has broken.
E942 Faulty EEPROM Data cannot be written on the EEPROM. Turn the power OFF.