When removing/installing the motor, unless the motor is
defective, loosen coupling setscrew 8 without loosening
coupling setscrews 6 and remove the motor with the coupling
installed.
* When the motor is separated
from the coupling, set the
clearance between the end face
of the motor and that of the
coupling to 0.5 mm when re-
assembling.
0.5 mm