– 116 –
Error
code
Description of error Cause Item to be checked
E489
Normal stitch portion,
normal feed amount
error
In the case the normal feed amount at
the normal portion exceeds the specied
feed range.
Reset the error. Then, re-input the
data.
Adjust the normal feed amount at
the normal portion of the pattern to a
value that falls within the limit range.
E490
Continuous sewing, cy-
cle sewing setting error
In the case the number of stitches of 1st
step is 0 (zero) of continuous sewing
pattern.
Reset the error. Then, re-input the
data.
E491
Cycle sewing pattern
error
In the case the pattern used for cycle
sewing invites an error.
Reset the error. Then, re-input the
data.
Re-input the pattern data which has
invited the error.
E493
Condensation custom
pattern width error
In the case the zigzag width of the con-
densation custom pattern exceeds the
max. limit.
Reset the error. Then, re-input the
data.
Adjust the zigzag width of the con-
densation custom pattern to a value
which falls within the max. limit.
E497
Max. zigzag width error The set zigzag width exceeds the max.
zigzag width limit.
Reset the error. Then, re-input the
data.
Adjust the zigzag width to a value
that falls within the max. zigzag width
limit.
E498
Stitch baseline position
error
In the case, though the set zigzag width
falls within the max. zigzag width limit,
the needle throwing position exceeds
the max. zigzag width limit.
Reset the error. Then, re-input the
data.
Adjust the stitch baseline to the posi-
tion that falls within the max. zigzag
width limit.
In the case a condensation custom
pattern is selected, check the con-
densation position of the pattern and
correct it appropriately if necessary.
E499 Simplied program fault
E704 Data failure (system-ver-
sion mismatch)
In the case the system version does not
match the machine head setting.
Re-write the system version to the
applicable one.
E731 Motor hole sensor fault In the case the motor signal is not input
properly.
Check whether the motor signal con-
nector has loosened or slipped o󰀨.
Check whether the motor signal cord
has broken by being caught under
the machine head.
Check whether the insertion direction
of the motor encoder connector is
correct.
E733 Reverse rotation of mo-
tor
When the motor runs at a speed of 500
sti/min. or more, the motor runs in the
reverse direction of the indicated direc-
tion of rotation.
Check whether the main shaft motor
encoder wire connection is correct.
Check whether the main shaft motor
wire connection for power is correct.
E750 Sewing machine stops In the case the optional-input safety
switch is pressed.

Table of Contents