EasyManuals Logo

JUKI SC-510 Engineer's Manual

JUKI SC-510
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
−44
Setting
range
1 to 20
1 to 20
1 to 20
1 to 20
1 to 20
0 to 999
(X10rpm)
0 to 999
(X10rpm)
on/off
on/off
Parameter 2
Invalid
Delay time (d.)
Delay time (d.)
Delay time (d.)
Number of
stitches (C.)
Number of
stitches (C.)
Repeat count
value (r.)
Delay time (d.)
Delay time (d.)
Delay time (d.)
Delay time (d.)
Delay time (d.)
Setting range
0 :
1 to 999 X 1 mS
0 : Waiting input until
condition is completed
1 to 999 X 1 mS
0 : Waiting input until
condition is completed
1 to 999 X 1 mS
0 : Command invalid
(1 to 999 stitches)
0 : Command invalid
(1 to 999 stitches)
0 : Immense
(1 to 999 times)
0 : Delay time invalid
0 to 999 X 1mS
0 : Delay time invalid
0 to 999 X 1mS
0 : Without delay
1 to 999 X 1mS
0 : Without delay
1 to 999 X 1mS
0 : Without delay
1 to 999 X 1mS
Remarks
Initial value
In case set value is "0", command is invalid. In case of other set
value, step moves to next one after lapse of delay.
When all conditions designated in input setting are completed (AND
input), step moves to next one.
When input conditions are not completed and delay time passed,
step jumps to that set in skip destination step No.
When either one of conditions designated in input setting is
completed (OR input), step moves to next one.
When input conditions are not completed and delay time passed,
step jumps to that set in skip destination step No.
When all input setting conditions are completed within set value of
number of stitches setting (ANDinput), step jumps to that
designated in skip destination step No. and moves to next step
after lapse of number of stitches.
When either one of input setting conditions is completed within set
value of number of stitches setting, step jumps to that designated
in skip destination step No. and moves to next step after lapse of
number of stitches.
Repeat is performed between steps designated in jump until repeat
count value is over. looping is performed immensely when set value
is "0".
(Caution) Do not perform nest input of this command.
Sewing machine speed can be set. It runs at set speed within set
delay time, and speed command is released after lapse of delay
time. Number of rotation at a lowest speed does not become less
than set value of function setting No. 35 Lowest speed by pedal.
In addition, maximum speed does not become more than set value
of function setting No. 96 Maximum number of rotation.
Maximum speed limitation value of sewing machine can be set.
Set speed limitation works within set delay time and speed limitation
command is released after lapse of delay time. Number of rotation
at slowest speed does not become less than set value of function
setting No. 35 Lowest speed by pedal. In addition, maximum speed
does not become more than set value of function setting No. 96
Maximum number of rotation.
LSW (depress front part of pedal command) is delayed. Command
is executed without delay time with delay time "0". For others, LSW
is invalid within set delay time and input of LSW is valid after setting
delay time.
Thread trimming motion is performed.
Command is executed without delay time with delay time "0". For
others, thread trimming command is performed within set delay
time.
Thread trimming output is delayed.
Command is executed without delay time with delay time "0". For
others, thread trimming delay command is performed within set
delay time and command is released after lapse of delay time.

Table of Contents