– 52 –
(2) Setting of accessory devices
SC-922 can be equipped with a needle thread clamp device, a center guide device, and the like as accessory
equipment on its machine head.
Even operations of some devices can be finely adjusted.
1. Displayed contents and setting method
Activate the setting mode with reference to “5.-(4) Function setting” and select function No. 141.
When function No. 141 is selected, the following are displayed.
A
B
Use the key or to select “_End”, “UT1_” or “UT2_” item.
When “UT1” or “UT2” is selected, use the key or to select the item
number of accessory device setting after “U1 0” or “U2 0” appears on the
indicator
A
.
Use the key or to enter the parameter to be set.
(Refer to “10.-(2), 2. Accessory device parameter list” for settable
parameters.)