Connection assignment
black, BK,
L
Phase conductor
brown, BR, ↓ Switched phase conductor
blue, BU,
N
Neutral conductor
grey, GY,
1
Connection push-button
PE
Protective conductor
Connect optional push-button (14) (see figure 9) or (see figure 10). This is only
necessary if manual operation is also desired.
Lit push-buttons may only be connected if they have an N connection terminal.
In the case of single devices, a 2-wire extension can be used as an alternative
to the push-button (14).
Screw the sensor cover (2) to connection box (1) with screws (10) and mount-
ing pins (9) (see figure 7).
Limiting the detection field using the push-on cover
The push-on cover can be used to limit the detection field, e.g. in order to mask out
interference sources.
Figure11: Push-on cover
Cover size Range on the ground (mounting height 3
m)
Complete push-on cover Ø approx. 4.5 m
Motion and presence detector