Area I cut out Ø approx. 7.5 m
Areas I + II cut out Ø approx. 12 m
without push-on cover Ø approx. 20 m
Pull off push-on cover.
Using scissors, cut out push-on cover along the marked lines as required.
Push on push-on cover.
Alternatively, the detection field can also be limited by switching off individual
sensors (see Commissioning).
6.2 Commissioning
Insert battery into IR remote control
The necessary settings are carried out using the "installation engineer" IR remote
control (see Accessories).
If multiple devices are within the range of the IR remote control, then align it so
that only the device to be operated can receive the signals.
Inserting the battery
Obey the battery safety instructions.
Keep contacts of batteries and device free of grease.
Insert the supplied battery with correct polarity (see IR remote control imprint).
Button assignment of the "installation engineer" IR remote control
Taste Funktion
1 s
Ů Short-time operation
30 s
Ů,
2 min
Ů,
5 min
Ů,
30 min
Ů
Set run-on time
ũ
Pressing for longer than 10 seconds
Saving ambient brightness as brightness
threshold
Ê, Ŧ, ŧ, Ũ Setting the brightness threshold
0-1 h
Ů Setting individual run-on time
Dyn.
Ů Pressing for longer than 10
seconds
Switching on the dynamic run-on time
PIR A
,
PIR B
,
PIR C
,
PIR A-C
Pressing for longer than 10seconds
Switching off the PIR sensors
PIR A
,
PIR B
,
PIR C
,
PIR A-C
Pressing for less than 10seconds
In the next 5seconds, use the
25%
,
50%
,
75%
and
100%
buttons to set the sensit-
ivity of the appropriate PIR sensor
25%
,
50%
,
75%
,
100%
Setting the sensitivity
Motion and presence detector
17 / 25
82593233 25.09.2023
J0082593233