Restoring the device to factory settings
■ Press the
Reset
button for longer than 10 seconds.
Function Value
Device function Motion detector
Operating mode Automatic operation
Sensitivity of PIR A-C 75%
Detection angle 360°, PIR A-C switched on
Switch-on brightness 10 lux
Run-on time 2 minutes
Dynamic run-on time switched-off
Short-time operation switched-off
Switch-off warning switched-off
Presence simulation switched-off
Test operation switched-off
If the
Reset
button is pressed for between 4 and 10 seconds, only a few func-
tions are terminated (see Button assignment of "installation engineer" IR re-
mote control).
7 Technical data
Rated voltage AC 110 ... 230 V ~
Mains frequency 50 / 60 Hz
Ambient temperature -5 ... +45°C
Standby power max. 0.3 W
Circuit breaker max. 16 A
Contact type ε
Detection angle 360°
Dimensions Ø×H 103 × 66 mm
Installation height 3 m
Detection field Ø approx. 20 m
Sensitivity 25 ... 100%
Brightness setting Approx. 5 ... 2000lx (and day operation)
Run-on time approx. 10 s ... 30 min
Short-time operation
Pulse duration approx. 0.5 s
Pulse stop approx. 3 s
Switching current at 35°C
Ohmic 16 A (AC1)
Fluorescent lamps 4AX
Motion and presence detector
22 / 25
82593233 25.09.2023
J0082593233