EasyManuals Logo

Jung IPR 300 SREG User Manual

Jung IPR 300 SREG
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
IP router
21.07.20202 / 40024021202
Intended use
- Connection between KNX devices and PC or other data processing devices via IP
- Operation as KNX area/line coupler or data interface
- Mounting on DIN rail according to EN 60715 in distribution boxes
Product characteristics
- KNXnet/IP routing for communication between KNX lines, areas and systems via IP network
- Support of KNX Data Secure from ETS version 5.7 upwards
- Support of KNX IP Secure from ETS version 5.7 upwards
- Telegram forwarding and ltering according to physical address or group address
- Max. 48 telegrams per second in IP secure mode
- LED display for KNX communication, Ethernet communication and programming mode
- Conguration via ETS, Telnet or software tool
- SNTP server, bu󰀨ered
- Commissioning with display support
- Max. 8 connections to IP terminal devices, e.g. for simultaneous visualisation and conguration
- Outage message of the KNX system to the IP system
- Electrical isolation between KNX and IP network
- Power consumption max. 1 W
4 Information for electrically skilled persons
Installation and electrical connection
DANGER
Electrical shock on contact with live parts in the installation environment.
Electrical shocks can be fatal.
Before working on the device, disconnect the power and cover live parts in the area!
Mounting
Mount IP router on DIN rail according to EN 60715 in distribution boxes.
Connection
Requirements:
- one Ethernet connection with 10/100 Mbit
- one KNX/EIB bus connection
For position of the connections see device components.
Connect LAN and KNX.
5 Commissioning
Switching on
After connecting, the device is switched on automatically. The product name and assigned IP address appear on the
display when switching on.
Boot procedure
The automatic boot procedure starts after switching on. The green POWER LED ashes during the assignment of the
IP address.
The IP address of the device appears in the display at the end of the boot procedure.

Other manuals for Jung IPR 300 SREG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jung IPR 300 SREG and is the answer not in the manual?

Jung IPR 300 SREG Specifications

General IconGeneral
BrandJung
ModelIPR 300 SREG
CategoryNetwork Router
LanguageEnglish