4.2.2 Starting procedure for the TFG
DANGER!
Risk of escaping liquid gas if the truck does not start
XNote the safety regulations governing the handling of liquid gas
((see "Safety regulations for handling diesel fuel and LPG" on page 39))
XClose the gas bottle shut-off valve.
XSet the key switch to "O"
XNotify your superior.
Procedure
Slowly open the shut-off valve on the
LPG bottle.
Insert the key in the key switch (79). Set
the key switch to “I”.
All the indicators go on briefly as a
function check and the (100) display is
activated.
Z All the warning indicators apart from the
engine oil pressure display (86), parking
brake (87), truck operational indicator
lamp (95) and charge current indicator
lamp (91) should go out after a short
while. If not, stop the start-up process
and rectify the fault.
Press the start button (78).
Z Only apply the starter for a maximum of
15 seconds without interruption. The truck is equipped with an immobiliser which
prevents it from starting again while the engine is running.
Release the start button as soon as the engine starts.
Test the brake pedal and parking brake.
The truck is now ready for operation.
Z All indicators except for the parking brake (87)
and the truck operational indicator (100) should
go out as soon as the engine starts. If not, stop
the engine immediately and rectify the fault.
km/h
R
69
9086 9187 95
100
S
T
A
R
T
78
79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jungheinrich TFG 320s and is the answer not in the manual?

Jungheinrich TFG 320s Specifications

General IconGeneral
BrandJungheinrich
ModelTFG 320s
CategoryForklifts
LanguageEnglish

Related product manuals