Review the chassis lifting guidelines described in “PTX10008 Installation Safety Guidelines and Warnings”
on page 445.
Ensure that the router has been safely powered off (see “Powering Off a PTX10000” on page 356).
CAUTION: When removing more than one router chassis from a rack, remove the routers
in order from top to bottom.
Ensure that you have the following parts and tools available to remove the router:
A mechanical lift rated for 500 lbs (226.8 kg)
A Phillips (+) screwdriver, number 2 or number 3, depending on the size of your mounting screws
To remove the router using a mechanical lift (see Figure 218 on page 360):
1. Use the appropriate Phillips (+) screwdriver to remove the 14 mounting screws that attach the chassis
flange to the rack.
2. Move the lift to the rack and position it so that its platform is centers about 0.5 in. (1.27 cm) below the
bottom of the router chassis and as close to it as possible.
3. Carefully slide the router from the adjustable mounting brackets attached to the rack onto the lift.
4. Move the lift away from the rack and lower the lift.
5. Use the lift to transport the router to its new location.
359