EasyManua.ls Logo

JVC D-ILA DLA-HD1-BC - Lamp Unit Handling

JVC D-ILA DLA-HD1-BC
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
(No.PA023)1-9
2.4 LAMP UNIT INSTRUCTIONS
Refer to the OPERATING INSTRUCTIONS for a detailed oper-
ating description.
2.4.1 Lamp life
Life of the projector lamp is about 2000 hours.
Lamp use time can be checked at the menu < Information > -
[Lamp time].
2.4.2 Operation when lamp use time exceeds 1900 hours
z 1900 to 2000 HOURS
Power ON: [LAMP] LED lights.
Operation : "Lamp replacement" message appears on
screen (press [EXIT] to extinguish).
z 2000 HOURS and after
Power ON: [LAMP] LED lights.
Operation : "Warning" and "Lamp replacement" messages
appear on screen, and "Warning" flashes.
Press [EXIT] button to extinguish the display. But after 1
hour, "Warning" and "Lamp replacement" again appear.
2.4.3 Handling cautions
Use a cross-head screwdriver to take out and reinstall the lamp
cover (1 screws) and lamp unit (2 screws). Refer to the OPER-
ATING INSTRUCTIONS.
Observe the following cautions.
- Be sure to disconnect the power cord from the AC power
source.
- The lamp remains quite hot after power off. Be sure to allow
plenty of time (30 minutes to 1 hour) to cool before proceed-
ing.
- The lamp can break if dropped or subjected to physical
shock.
- Use care not to directly touch or soil the lamp projecting
(glass) face.
When installing the lamp unit, observe the interior projections
of the lamp cover are securely inserted into the holes of the
projector. Since the lamp cover projections engage the inter-
lock switch part of the protector circuit (normal operating state),
be sure the cover is properly positioned and secure with
screws.
The replaced old lamp (depleted lamp unit) can be discarded
in the same manner as a fluorescent lamp. Check local ordi-
nances and dispose of the used lamp as prescribed.
2.4.4 Lamp use time reset
Be sure to reset the Lamp use time after replacing the lamp
unit. Unless reset, the projector will cease operation (lamp will
not light) when 2000 hours are reached.
Conversely, reset the use time only after replacing the lamp.
RESETTING
(1) Set for stand-by mode.
(2) In sequence, press the [EXIT], [ENTER] and [HIDE] but-
tons.
(3) Press the [] button for more than 2 seconds.
The STAND-BY and LAMP LEDs alternately flash for
about 3 seconds, then only the STAND-BY LED lights
steadily.
RESET AFTER REPLACING PROCESSOR PWB ASS'Y
The lamp use time data are stored in memory on the PRO-
CESSOR PWB ASS'Y and need to be reentered after replac-
ing the PROCESSOR PWB ASS'Y. Use the special software
and a personal computer to reenter the data. Afterwards, con-
firm the mode has been returned to that prior to board replace-
ment.
LAMP UNITBHL5009-S (HD1-BE/BU)
BHL5009-SC (HD1-BC only)

Related product manuals