Keycards
Kaba Ilco Lodging Access Control System 93
specific firmware versions will support time zones (for details please contact Kaba
Technical Support). All RAC 4 & 4XT card readers support time zones.
Applicable Keycards: Section, Floor, Group, Zone, Area and Grand Master
Description: Up to six time zones can be used to limit the validity of staff
keycards to certain hours:
1) Time Zone 0 00:00 to 04:00 hrs.
2) Time Zone 4 04:00 to 08:00 hrs.
3) Time Zone 8 08:00 to 12:00 hrs.
4) Time Zone 12 12:00 to 16:00 hrs.
5) Time Zone 16 16:00 to 20:00 hrs.
6) Time Zone 20 20:00 to 24:00 hrs.
Press the right <
X
> arrow to access the available timezones.
Each Timezone that is set to "YES" in the Fixed Time Zone Menu (refer
to section 4.6 part 7.1 – Fixed Time Zones) will be displayed and defaulted
to NO. Press the left <
W
> or right <
X
> arrow to set the value for any
desired Timezone to YES. When the keycard is encoded the staff will only
have access to locks during the timezone periods set to YES.
Use the AUTO option in the FDU Features Menu to give
access to a time zone on all staff keycards. Note that if time
zones are enabled, but no time zones are selected using the
AUTO or YES options, the keycard will never
be valid, and
the FDU will warn the user with an error message.