Online operation with firmware option Access Manager
k4evo707en-2012-07 35
4.6 Antenna adaptation
The slide switch can be used to calibrate the antenna for mounting on metallic or non-metallic
bases.
Always put the slide switch in the Air position, except when using a metallic base. The slide switch
is set to the Air position on delivery (default).
Position Meaning
In Air position for a non-metallic base;
(default)
In Metal position for a metallic base
4.7 LED display
Displays the access decision and operating state by means of the central light symbol (red/green)
and an acoustic signal transmitter (buzzer).
Error correction tips can be found in Chapter 9/Page 79.
The relevant chapters contain descriptions of signaling during a factory reset and firmware update.
Signaling (default) Meaning
Access signal
Green goes off/on briefly and 1x short beep
Flashing red/intermittent beep
LED flashes green/red and beep
Access authorized/Access allowed
Access not authorized
Access allowed with prompt to update the
badge
Operating state
Green on
Red on
Ready for booking
Access point blocked
Air
Metal
Air
Metal