Do you have a question about the Kaco blueplanet gridsave 92.0 TL3-S and is the answer not in the manual?
AC Grid Frequency | 50 Hz / 60 Hz |
---|---|
Nominal AC Current | 133 A |
THD | <3% |
Max. DC Voltage | 1100 V |
Topology | Transformerless |
Operating Temperature Range | -25 °C to +60 °C |
Relative Humidity | 0 - 95 % (Non-condensing) |
Ingress Protection | IP65 |
AC Nominal Power | 92 kW |
Maximum AC Power | 92 kVA |
MPP voltage range | 450 V - 850 V |
Cooling | Forced Air |
Dimensions (W x H x D) | 1100 mm |
Communication | Ethernet, RS485 |
Certifications | IEC 62109, CE |
Power Factor | 0.8 leading - 0.8 lagging |
Details current warranty conditions.
Mentions open source software usage and licensing.
States the document's purpose and validity.
Explains the document's structure and symbols.
Describes symbols for hazards and connections.
Details information found on the product's name plate.
Instructs on handling device warning stickers.
Defines the qualifications required for personnel.
Describes the device's purpose and approved applications.
Lists integrated monitoring and protection functions.
Explains the necessity of an external EMS/PMS for operation.
Details available interfaces for communication and monitoring.
Provides detailed electrical specifications for different models.
Specifies installation height and ambient temperature limits.
Lists items included with the bidirectional feed-in inverter.
Provides instructions and cautions for safe transport.
Details requirements for installation space and surface.
Guides on lifting and fitting the device onto the mount.
Guides on connecting electrical components.
Details steps for AC connection and earthing.
Explains DC connection procedures and polarity checks.
Details various interface connections.
Lists prerequisites for device commissioning.
Outlines different methods for initial device setup.
Guides through the initial setup wizard steps.
Explains the meaning of device LEDs for operating states.
Describes how the user interacts with the device's interface.
Provides an overview of the web application's menu layout.
Outlines steps for connecting and monitoring the device.
Provides instructions for updating device firmware.
Explains how to establish Modbus communication.
Explains the role and control of reactive power in energy supply.
Details methods for regulating active power output.
Explains grid support during voltage disturbances.
Covers functions like power limitation and islanding detection.
Guides on checking for external damage and operating status.
Provides instructions for cleaning device components.
Guides on removing and replacing internal or external fans.
Lists common faults, their causes, and rectification steps.
Describes how to safely switch off the device.
Provides steps for disconnecting AC and DC cables.
Guides on removing the device from its mount.
Confirms compliance with EU directives and standards.
Lists relevant standards and directives the device conforms to.