10.15.1 Cleaning the solenoid valve
Fig. 32 Cleaning the solenoid valve
1 Solenoid valve
2 Screw
3 Coil
4 Armature
5 Spring
6 Piston
7 Enclosure
8 Connecting socket
9 Arrow showing flow direction
1. Disconnect the connecting socket from the valve.
2. Undo the screw and carefully remove the coil.
3. Clean the armature and piston.
Change the spring if damaged or worn.
4. Reassemble the valve.
5. Open the user's shut-off valve between the machine and the air system.
6. Start the machine and visually check for leaks.
10 Maintenance
10.15 Solenoid valve maintenance
60
Service Manual 2-stage piston compressor
EPC No.: 9_9431_02 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER EPC Series and is the answer not in the manual?

KAESER EPC Series Specifications

General IconGeneral
TypeRotary Screw Compressor
Drive TypeDirect Drive
Cooling SystemAir-cooled
Control SystemSigma Control 2.0
WeightVaries depending on model
Noise Level62 - 75 dB(A) (depending on model)