12 Decommissioning, Storage and Transport
12.1 De-commissioning
De-commissioning is necessary, for example, under the following circumstances:
the machine is temporarily not needed,
the machine is to be moved to another location,
the machine is to be scrapped.
Temporary de-commissioning
Precondition The machine can be started at regular intervals.
Run the machine once a week under load for at least 30 minutes to ensure corrosion protection.
Long-term de-commissioning
Precondition The machine must have run for at least 30 minutes before before long-term de-commissioning.
The mains disconnecting device is switched off.
The disconnecting device is locked in the off position.
A check has been made that no voltage is present.
Machine fully vented (no pressure).
1. Allow the machine to cool down completely.
2. Spray the valves and cylinder bore with Shell Ensis 20 preserving oil.
The preserving oil does not need to be removed when re-commissioning.
3. Drain condensate.
4. Disconnect all air and electrical connections.
5. Spray all contacts and terminals with a preservative (e.g. Rivalto, W.S.X.).
12.2 Packing
A wooden crate is required for overland transport to protect the machine from mechanical damage.
Consult KAESER Service for advice on packing for sea or air transport.
Material Desiccant
Plastic sheeting
Wooden transport crate
Precondition The machine is decommissioned.
Machine is dry and cooled down.
1. Wrap the machine in plastic sheeting.
2. Place sufficient desiccant (e.g. silica gel) inside the plastic sheeting.
12 Decommissioning, Storage and Transport
12.1 De-commissioning
72
Service Manual 2-stage piston compressor
EPC No.: 9_9431_02 E

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER EPC Series and is the answer not in the manual?

KAESER EPC Series Specifications

General IconGeneral
TypeRotary Screw Compressor
Drive TypeDirect Drive
Cooling SystemAir-cooled
Control SystemSigma Control 2.0
WeightVaries depending on model
Noise Level62 - 75 dB(A) (depending on model)