EasyManua.ls Logo

Kaise 7050 User Manual

Default Icon
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Question and Answer IconNeed help?

Do you have a question about the Kaise 7050 and is the answer not in the manual?

Kaise 7050 Specifications

General IconGeneral
Diode TestYes
Continuity TestYes
Continuity BuzzerYes
DC Voltage Ranges1000V
AC Voltage Ranges750V
DC Current Ranges10A
AC Current Ranges4000μA, 40mA, 400mA, 10A
Frequency Ranges5Hz, 50Hz, 500Hz, 5kHz, 50kHz, 500kHz, 5MHz
Power Supply9V battery
Dimensions85mm

Summary

Safety Precautions and Procedures

Preliminary Safety Information

General safety guidelines for multimeter use, including pollution degree and voltage category.

During Use Safety

Critical safety recommendations for operating the multimeter during measurements.

After Use Procedures

Steps to take after completing measurements and for long-term storage.

General Description and Preparation

General Description

Overview of the multimeter's capabilities and functions, including measurement types.

Initial Setup

Instructions for initial checks, packaging verification, and handling potential transport damage.

Supply Voltage

Details on the batteries required for the multimeter's operation.

Calibration and Storage

Information on calibration guarantees and proper storage conditions for accuracy.

Operating Instructions

Instrument Description

Identifies and explains the components and controls of the analog multimeter.

DC Voltage Measurement

Procedure for measuring DC voltage, including range selection and probe connection.

AC Voltage Measurement

Procedure for measuring AC voltage, including range selection and probe connection.

DC Current Measurement

Procedure for measuring DC current, including safety and connection steps.

Battery Check

Instructions for testing the condition of 1.5V and 9.0V batteries.

Resistance Measurement

Steps for measuring resistance, including zero adjustment and safety precautions.

Continuity Test

Procedure for performing continuity tests using the multimeter.

Decibel Measurement

Guide for measuring decibel values, including range selection and correction factors.

LED Test

Procedure for testing LEDs, including polarity and expected readings.

Preventive Maintenance

General Maintenance Information

Guidelines for maintaining the multimeter's precision and avoiding damage.

Batteries Replacement

Detailed steps for safely replacing the multimeter's batteries.

Fuses Replacement

Instructions for replacing fuses, emphasizing correct type and safety.

Cleaning Instructions

Proper methods for cleaning the multimeter's exterior.

Technical Specifications

DC Voltage Specifications

Accuracy and sensitivity details for DC voltage measurements.

AC Voltage Specifications

Accuracy and sensitivity details for AC voltage measurements.

DC Current Specifications

Accuracy and voltage drop details for DC current measurements.

Resistance Specifications

Accuracy details for various resistance measurement ranges.

Battery Test Specifications

Test current details for battery testing at different voltage ranges.

Safety Specifications

Compliance standards for insulation, pollution, and overvoltage.

General Data

Physical dimensions, weight, battery types, fuse ratings, and display type.

Environmental Conditions

Operating and storage temperature, humidity, and EMC standards compliance.

Standard Accessories

List of items included in the multimeter packaging.

Service and Warranty

Warranty Conditions

Details on the warranty period, coverage, and exclusions.

Service Procedures

Instructions for troubleshooting and returning the equipment for service.

Related product manuals