Diode Test | Yes |
---|---|
Continuity Test | Yes |
Continuity Buzzer | Yes |
DC Voltage Ranges | 1000V |
AC Voltage Ranges | 750V |
DC Current Ranges | 10A |
AC Current Ranges | 4000μA, 40mA, 400mA, 10A |
Frequency Ranges | 5Hz, 50Hz, 500Hz, 5kHz, 50kHz, 500kHz, 5MHz |
Power Supply | 9V battery |
Dimensions | 85mm |
General safety guidelines for multimeter use, including pollution degree and voltage category.
Critical safety recommendations for operating the multimeter during measurements.
Steps to take after completing measurements and for long-term storage.
Overview of the multimeter's capabilities and functions, including measurement types.
Instructions for initial checks, packaging verification, and handling potential transport damage.
Details on the batteries required for the multimeter's operation.
Information on calibration guarantees and proper storage conditions for accuracy.
Identifies and explains the components and controls of the analog multimeter.
Procedure for measuring DC voltage, including range selection and probe connection.
Procedure for measuring AC voltage, including range selection and probe connection.
Procedure for measuring DC current, including safety and connection steps.
Instructions for testing the condition of 1.5V and 9.0V batteries.
Steps for measuring resistance, including zero adjustment and safety precautions.
Procedure for performing continuity tests using the multimeter.
Guide for measuring decibel values, including range selection and correction factors.
Procedure for testing LEDs, including polarity and expected readings.
Guidelines for maintaining the multimeter's precision and avoiding damage.
Detailed steps for safely replacing the multimeter's batteries.
Instructions for replacing fuses, emphasizing correct type and safety.
Proper methods for cleaning the multimeter's exterior.
Accuracy and sensitivity details for DC voltage measurements.
Accuracy and sensitivity details for AC voltage measurements.
Accuracy and voltage drop details for DC current measurements.
Accuracy details for various resistance measurement ranges.
Test current details for battery testing at different voltage ranges.
Compliance standards for insulation, pollution, and overvoltage.
Physical dimensions, weight, battery types, fuse ratings, and display type.
Operating and storage temperature, humidity, and EMC standards compliance.
List of items included in the multimeter packaging.
Details on the warranty period, coverage, and exclusions.