E. ORDINARY CLEANING AND MAINTENANCE
e.1 Cleaning and maintenance by the costumer
Before lighting the stove, it is advisable to clean the inside of the stove.
● Open the door and vacuum the fire table.
● Remove the great, verify its cleanliness and clean the holes if necessary.
● Vacuum the grate space and clean the contact borders.
● Replace the grate, making sure that its borders adhere perfectly to their designed place.
● Empty the ashtray.
● Close the ashtray and the door.
e.2 Periodic maintenance by the Assistance Center
Every 6 months
● Generally clean the inside and outside of the fumes pipe of the stove.
● Remove the furnace’s internal covering; accurately clean and remove the incrustations inside
the crucible and its space.
● Clean the fans and check the mechanism of the plays and of the fixings.
● Clean, inspect and remove the incrustations of the lighting resistance and its space.
● Clean the display and the remote control.
● Inspect the electrical cables, the connections and the supply cable.
● Clean the pellet tank and check the screw.
● Perform a functional test, load the screw, and light the stove.
Every 12 months:
In addition to all the operations required every 6 months:
● Substitute the lighting cartridge (in case of a daily use with more than three lightings a day).
● Inspect and clean the fumes’ channel.
● Inspect and check the flue’s draught (possibly, perform or order a cleaning).