P30UDP commands
UDP Programmers Guide V2.01
16
© KEBA
Field Contents Additional Description
Backend
0 No backend communication is present.
1 Backend communication is present.
timeQ
0
Not synced time (for more information see
“setdatetime”).
X
Strong synced time (for more information see
“setdatetime”).
2
Weak synced time (for more information see
“setdatetime”).
Sec uint32
Current state of the system clock in seconds
from the last startup of the device.
3.2.3 UDP command: report 2
Command structure
Command Parameters Additional Description
report 2
- -
Reply structure
Field Contents Additional Description
ID 2 ID of the report
State
0 Startup
1
Not ready for charging
Charging station is not connected to a vehi-
cle, is locked by the authorization function or
another mechanism.
2
Ready for charging and waiting for reaction
from vehicle.
3 Charging
4 Error is present
5
Charging process temporarily interrupted be-
cause temperature is too high or any other
voter denies.
Error1 uint16 Decimal number defining the error
Error2 uint16 Decimal number defining the error