P30 UDP commands
UDP Programmers Guide V2.01
17
© KEBA
Field Contents Additional Description
Plug
0 No cable is plugged.
1 Cable is plugged into charging station.
3
Cable is plugged into charging station and
locked.
This is the default idle state for all devices
with permanently attached cable.
5
Cable is plugged into charging station and
vehicle but not locked.
7
Cable is plugged into charging station and
vehicle, furthermore the cable is locked.
Charging is not possible until plug state “7” is
reached.
AuthON
0 Authorization function is deactivated.
1 Authorization function is activated.
Authreq
0
Authorization via RFID card is not required.
OR
The authorization via RFID card was already
performed.
1 Authorization via RFID card is required.
Enable sys
0 Charging state cannot be enabled.
1 Charging state can be enabled.
Enable user
0 Device is disabled (e.g. via “ena 0”).
1 Device is enabled.
Max curr
uint16
Possible values:
0; 6000 - 32000
Current value in mA offered to the vehicle via
control pilot signalization. (Signal type: PWM)
Max curr %
uint16
Possible values:
100 - 533; 1000
Duty cycle of the control pilot signal. The unit
displayed is not % but 0.1%, which means
that the value “1000” stands for a duty cycle
of 100%. For more information concerning
the control pilot refer to IEC 61851-1.
Curr HW
uint16
Possible values:
0; 6000 - 32000
Maximum current value in mA that can be
supported by the hardware of the device.
This value represents the minimum of the
DIP switch settings, cable coding and tem-
perature monitoring function.
Curr user
uint16
Possible values:
0; 6000 - 63000
Current setting in mA defined via UDP cur-
rent commands. (Default: 63000 mA)
Curr FS
uint16
Possible values:
0; 6000 - 63000
Current setting in mA defined via fail-
safe function.
Tmo FS
uint16
Possible values:
0; 10 - 600
Communication timeout in seconds before
triggering the Failsafe function.
Curr timer
uint16
Possible values:
0; 6000 - 63000
Current value in mA that will replace the set-
ting in the “Curr user” field as soon as “Tmo
CT” expires.