P30 UDP commands
UDP Programmers Guide V2.01
19
© KEBA
Field Contents Additional Description
E total
uint32
Possible values:
0 - 999999999
Total energy consumption (persistent, device
related) in 0.1 Wh.
Max. value is 99999999.9 Wh (higher values
will cause a counter overflow).
Serial String (8 chars) Serial number of the device
Sec uint32
Current state of the system clock in seconds
from the last startup of the device.
Example
Charging station is not connected to a vehicle. Vehicle is charging.
3.2.5 UDP command: report 1xx (historical log entries)
With the commands report 101 up to report 130 you can read the history
of the last 30 charging sessions. report 100 shows the latest charging ses-
sion. After a reboot, the report will deliver all zero values. If a new session is
started by plugging in the vehicle, a new Session ID is created in report
100 and all the available values (start time, start energy value, RFID token
code) are filled. If the session ends, the end values (end time and end rea-
son) will also be added, and report 100 is shifted to report 101.
Command structure
Command Parameters Additional Description
report 100
- -
Reply structure
Field Contents Additional Description
ID 100 ID of the report
Session ID uint32
ID of the current charging session. This value
will be assigned automatically and is not re-
settable. This value is incremented session
by session. Due to the high maximum value
(over 4 billion possible IDs), the session ID
can be considered unique.